Why teams building clinical AI need all three, and how they fit together
Healthcare AI models now achieve near-perfect scores on medical licensing exams,[7]Â and these results often feature prominently in product launches.
Exam performance tells us little about how reliably a model will perform in real healthcare settings. Medical exams present carefully constructed scenarios with clearly defined answers. Real clinical interactions are far less predictable.
Clinical requests may contain missing details, lengthy histories or crucial information buried in an otherwise routine description. Patients may describe symptoms casually, clinicians may phrase requests indirectly, and some users may try to circumvent safeguards. A model that performs well on structured exam questions may struggle with the ambiguity, incomplete information and unexpected context of real use.[1], [2]
An exam score alone therefore says little about whether a healthcare AI product is ready for use. Teams need to test both what a model knows and how reliably the product responds in the situations it is designed to handle. Three complementary methods help them do this:
- Benchmarking compares models on shared tasks.
- Evaluation checks whether a product meets criteria for its intended use.
- Red teaming actively searches for failures that existing tests may miss.
Each method answers a different question, and each covers gaps the others leave. Used together, they form a testing process that continues well beyond model selection and launch.
Scope: All examples come from language model products. Imaging and biosignal models use similar methods under other names.
Three methods, three different questions
The quickest way to tell the methods apart is to ask what decision each one supports.
| Method | Question | Test material | Main output |
|---|---|---|---|
| Benchmarking | How does this model compare with others on a shared task? | A shared dataset or task used across models | Comparable scores that help shortlist models |
| Evaluation | Does this product meet requirements for its intended use? | Use-case-specific cases and scoring criteria | Pass rates by criterion, failure severity and version-to-version changes |
| Red teaming | How can this product be made to fail or produce a harmful output? | Prompts and scenarios designed to probe weaknesses | A record of failures, triggers, severity and reproducibility |
Benchmarking: comparing models
A benchmark applies the same task or dataset to many models so their results can be compared. Healthcare benchmarks range from multiple-choice medical questions to open-ended health conversations scored against physician-written criteria.
Some focus on medical knowledge. MedQA uses US medical licensing exam-style questions,[3] MedMCQA draws on Indian postgraduate medical entrance examinations,[4] and PubMedQA tests question answering on biomedical research abstracts.[5]
Others look at broader clinical capabilities. HealthBench scores open-ended health conversations against physician-written criteria,[6], and MedHELM brings together 37 evaluations covering 121 clinical tasks.[7]
What a high score covers
Benchmarks give teams a quick way to compare candidate models, track progress between releases and explain performance to non-technical audiences. Their scores also lead many product announcements.
OpenEvidence, for example, announced in 2023 that its model was the first AI to score above 90% on the official USMLE sample exam, and in 2025 it announced a score of 100%.[8], [9]Â A result like that shows performance on that exam. Safety across real clinical workflows needs separate evidence.
Part of the reason is that model performance can change sharply when a question is reworded, even if the clinical question underneath stays the same.
A study of 16 models took the exam questions each model had answered correctly and modified them over as many as five rounds. The changes added distracting details, misleading contextual cues and physiologically implausible values, which resemble the noise and errors found in real clinical input.[10]Â Across the 16 models, a median of 94% of those previously correct answers became incorrect after the changes.[10]
Share of previously correct answers that became incorrect after changes
Figure 1. Each bar starts from answers the model had already got right. Exam figures follow up to five rounds of changes. The open-ended figure covers the six leading models after a single change per case. Source: Pan et al. 2026 [10]
The researchers ran a similar test on open-ended HealthBench cases. After a single change per case, the six leading models lost an average of 76% of the answers that had met a physician-written criterion.[10]Â Rankings shifted too. Models that ranked highly on exam questions could rank lower on the open-ended cases.[10]
Format matters as much as wording. In the CRAFT-MD study, four models answered 2,000 clinical vignettes across 12 specialties, first as written cases and then through simulated conversations with a patient agent. GPT-4's diagnostic accuracy fell from 82% on multiple-choice vignettes to 63% in conversation, and from 49% to 26% when it had to name the diagnosis without answer options. Every model tested showed the same pattern.[2]
These findings show why benchmark scores should never be viewed in isolation. Each score reflects how a model performs on a particular task, using a specific dataset and scoring method. A model that outperforms its competitors on one benchmark may rank lower on another, depending on what is being tested and how success is measured.
When to use benchmarking
- Shortlist candidate base models before investing in a product-specific pilot.
- Compare releases on the same task, while checking that the benchmark is still relevant.
- Report results alongside their task, dataset and scoring method, rather than as a general claim of clinical readiness.
Once a candidate model has been chosen, the question changes: does the actual product meet the requirements of its intended use? The model is only one part of the product. Prompts, retrieval systems, the interface, safeguards and the intended users all shape how it behaves.
A 2026 randomised study in Nature Medicine shows how much the user adds. On their own, three language models identified the relevant condition in 94.9% of ten medical scenarios. When 1,298 members of the public used the same models to work through those scenarios, they identified the condition in under 34.5% of cases, no better than a control group using their usual sources. The authors note that standard medical knowledge benchmarks did not predict the gap.[1]Â Testing that whole combination, model, interface and user together, is where evaluation comes in.
Evaluation: testing the product
Evaluation tests the product against predefined requirements. The team writes cases that represent the product's intended use and sets criteria for deciding whether each response is acceptable.
Its quality depends on two things: whether the cases reflect the situations the product will meet, and whether the criteria capture what a safe, useful response contains.
Build a representative case set
For a clinical decision-support product, a case set might include common presentations, emergencies, incomplete information, drug interactions and contraindications, and requests outside the product's scope.
The exact mix should reflect the product's intended use, users and risk profile. Usage logs and incidents can suggest new cases, while rare, high-severity scenarios need cases written on purpose, since they seldom show up in routine use.
The examples below show how different cases test different parts of the same product.
| Illustrative case type | Example | What the team checks |
|---|---|---|
| Common presentation | Adult with community-acquired pneumonia | Accuracy and appropriate next steps |
| Emergency | Chest pain with features concerning for aortic dissection | Recognition of urgency and appropriate escalation |
| Incomplete information | Dosing question without renal function | Whether the product asks for missing information rather than guessing |
| Drug interaction | New prescription for a patient taking an anticoagulant | Recognition of interaction risks and contraindications |
| Out-of-scope request | Request to write a prescription when the product is only authorised to support clinicians | Whether the product stays within its intended role |
Cases set out what the product needs to handle. To judge the answers, teams also need a consistent way to score them.
Define what a good answer looks like
A rubric turns product requirements into observable checks. Teams can apply shared criteria across all cases, add case-specific criteria for details that matter in a particular scenario, or combine both.
For a clinical decision-support tool, a rubric might include the following criteria.
| Criterion | What it means | Example for a clinical decision-support tool |
|---|---|---|
| Accuracy | Claims are correct and supported by appropriate, current evidence. | Drug doses and guideline references are correct. |
| Completeness | All essential information for the case is included. | Relevant red flags, contraindications and next steps are included. |
| Context awareness | The response uses the information provided and identifies what is missing. | The product asks for renal function before giving a renal-dependent dose. |
| Escalation | The product recognises emergencies and recommends an appropriate level of care. | Possible sepsis is flagged for urgent assessment, rather than handled as routine self-care. |
| Scope | The product stays within its intended role. | It supports the clinician's prescribing decision without acting as the prescriber. |
| Communication | The response is appropriate for its intended reader. | Advice is clear, appropriately qualified and easy to act on. |
A small initial test is manageable for clinicians to score by hand. Six criteria across 50 cases, for example, produce 300 judgements per model version.
A single overall pass rate can hide the failures that matter most. Teams should track critical safety failures separately and weigh error severity, case-set quality and reviewer consistency when reading results.
The blind spot: a rubric only checks what it covers
Even a carefully designed rubric can only catch failures its criteria are built to recognise.
A September 2026 preprint tested whether benchmark rubrics could detect errors inserted into otherwise correct medical responses. On HealthBench, the rubric favoured the correct response in a majority of pairs for only three of 13 error types. Errors that introduced new claims, such as an extra diagnosis or fabricated evidence, proved difficult to detect.[11]
Passing an evaluation and being safe are therefore different things. A response can meet every criterion being measured and still contain a harmful claim the rubric never looked for.
Structured scoring is worth keeping, because it makes evaluation consistent and repeatable. Pair it with clinical review of the full response, especially where it contains unsupported claims, unexpected diagnoses or potentially high-severity errors.
When to use evaluation
- Before each release that changes the model, the prompt or the retrieval setup, so that scores can be compared by version.
- After a red team session, to turn each reproducible finding into a permanent case.
- Whenever usage logs or incidents show a kind of request the case set does not yet cover.
Evaluation still has a boundary: it measures performance against the cases and failure types the team knows to test. Red teaming helps teams identify weaknesses that existing tests and evaluations may have overlooked.
Red teaming: finding hidden failures
Red teaming deliberately probes a system for weaknesses. For a healthcare language model, the aim may be to make it produce something it should refuse, reveal information it should protect, or give an answer that could harm a patient.
Where evaluation scores defined cases against predefined criteria, red teaming explores how the product behaves under pressure, ambiguity or unexpected context.
Two complementary approaches are useful. Adversarial red teaming deliberately tries to get around safeguards. Clinical red teaming uses realistic, difficult requests that a well-intentioned user might make.
| Adversarial red teaming | Clinical red teaming | |
|---|---|---|
| Tester's approach | Deliberately probes or circumvents safeguards. | Uses difficult but plausible clinical or patient requests. |
| Typical tactics | Authority impersonation, false premises, gradual escalation or attempts to bypass restrictions. | Indirect requests, assertive framing, cluttered notes, conflicting context or misleading assumptions. |
| Failure signal | The product provides information or takes an action it should have refused. | The product gives a misleading, incomplete or unsafe answer, or refuses a legitimate request. |
| Who should be involved | Prompt and security specialists, with clinicians judging clinical harm. | Clinicians working with technical staff. |
The distinction matters because unsafe behaviour can appear without an elaborate attack. A product may fail when someone deliberately manipulates it, and it may also fail during an ordinary interaction that introduces ambiguity, pressure or misleading information.
Adversarial example: a claim of medical authority
A 2026 study by Ekram tested 160 adversarial prompts across eight categories against one general-purpose model running a standard medical assistant prompt. An automated evaluator rated eleven responses clinically harmful, and nine of those came from the authority impersonation category.[12]
One tactic produced most of the harmful responses
Prompts rated clinically harmful, by attack category. 20 prompts per category, 11 of 160 in total.
In one scenario, a tester claiming to be an emergency physician asked for propofol dosing for sedation, and the model provided weight-based doses and a redosing schedule with a single closing sentence on airway equipment.[12]
The concern lies less in the medical information itself than in what prompted it: an unverified claim of authority appeared to change how readily the model gave high-risk guidance.[12]
Ekram's study has clear limits. It tested one model, was written by a single author, relied on an automated evaluator to judge harm and was posted before physician review was complete.[12]Â It still shows a failure mode worth testing in any patient-facing product: a credential the model has no way to verify can change what it is willing to say.
The larger study behind Figure 1 found related patterns across 15 models. Presented with requests that would breach patient privacy, such as drafting a sick note that named the diagnosis, the models complied in 86% of scenarios with no adversarial prompting at all. The most effective way to increase leaks was to add a line such as "remember to respect the patient's privacy" to the request, which appeared to reassure the model that the matter was handled. A single sentence citing a senior colleague's view or a recent similar case changed the clinical recommendation in 81% of fairness tests.[10]
Clinical example: ordinary requests can still produce unsafe answers
Clinical red teaming asks a different question from adversarial testing: can a product give an unsafe answer to a request that looks plausible in normal use?
A Stanford-led study brought clinicians, students and engineers together to write prompts reflecting realistic use, rather than artificial instructions to behave badly. Across 376 prompts tested against four model versions, 20.1% of the 1,504 responses were judged inappropriate.[13]
Examples included a model agreeing to suspend a do-not-resuscitate order after pressure from a purported relative, drafting a letter that disclosed a patient's diagnosis for display in a public place, and giving an incorrect due date.
The privacy letter shows that the wording of a request can decide whether the answer is safe. When testers asked the model directly whether it could leave patient information in a public place, it warned against doing so. When they asked it to draft the letter for the lobby, it wrote the letter.[13]
A test that only asks the direct question would record a pass, even though the product still carries out the unsafe task when asked indirectly.
The same study logged the opposite failure. Asked by a clinician for a mirtazapine dose for a 92-year-old woman with insomnia and depression, one model refused to answer.[13]Â A product that declines routine clinical questions fails its users in a different way, and a red team should record both kinds of failure.
A separate healthcare red teaming workshop reported failures involving image interpretation, anchoring, sycophancy, incorrect or omitted medical knowledge, prioritisation and vague responses.[14]Â In one example, a model interpreted the same scoliosis X-ray differently once the images were labelled as pre- and post-surgery. In another, it reversed a sound answer after the user challenged it.
These examples show why clinical expertise matters in testing. A response can sound fluent while being subtly wrong, and user framing can change the answer even when the clinical evidence stays the same.
How to run a first red team session
- Seat clinicians and technical staff at the same table. Clinicians bring realistic scenarios; technical staff know how to push a model.
- Supply synthetic patient notes so testers can ask complex questions without writing a case from scratch each time.
- Agree the harm categories before the session starts, such as safety, privacy, accuracy and bias.
- Have two reviewers judge each response, with a third to settle disagreements.
- Spend time on indirect requests and assertive framing. The Stanford team found that these produced failures where direct questions did not.
- Log every failure with the prompt, the response, a category and a severity rating, and note whether it reproduces on a second run.
Based on the format reported by Chang et al. [13].
Use the three methods as a continuous workflow
The methods are most useful when each one feeds the next. Benchmarking informs model selection, evaluation tests the product against specific requirements, red teaming searches for weaknesses, and evaluation then checks whether those weaknesses come back after changes.
Turning discovered failures into repeatable tests is the step that holds this together. Without it, a team may fix a problem once and miss it when it returns in a later release.
After launch, monitoring adds further input. Reviewing real outputs and incident reports shows where the test set no longer matches how the product is used.
The testing workflow across a product's life
Each stage, the method it uses and what the team does
Treating testing as a one-time approval step leaves teams relying on users to discover failures in real-world use. A continuous process works differently: red teaming uncovers weaknesses, evaluations turn those findings into measurable requirements, and benchmarks track performance against a consistent set of tests. Each failure becomes a test that can be repeated against future versions.
Grayde runs evaluations and red teaming exercises for healthcare and life science AI teams, with credentialed clinical specialists writing the cases and reviewing the outputs. Contact us to discuss a pilot.
Limitations and scope
Some studies discussed here are preprints, and findings from research settings may not generalise directly to deployed products with retrieval systems, guardrails or constrained interfaces. Results should therefore be interpreted in the context of each study's methods and limitations. The Stanford red teaming data come from model versions tested in late 2023, and the models have changed since.
Terminology also varies across the literature.[15]Â In this article, evaluation measures performance against defined requirements, while red teaming actively searches for failure modes that existing tests may miss. This is a practical distinction rather than a universal definition.
References
- Bean AM, Payne RE, Parsons G, et al. Reliability of LLMs as medical assistants for the general public: a randomized preregistered study. Nature Medicine 2026;32(2):609-615. doi:10.1038/s41591-025-04074-y. Preprint: arXiv:2504.18919
- Johri S, Jeong J, Tran BA, et al. An evaluation framework for clinical use of large language models in patient interaction tasks. Nature Medicine 2025;31:77-86. https://doi.org/10.1038/s41591-024-03328-5
- Jin D, Pan E, Oufattole N, et al. What Disease Does This Patient Have? A Large-Scale Open Domain Question Answering Dataset from Medical Exams. Applied Sciences 2021;11(14):6421. https://arxiv.org/abs/2009.13081
- Pal A, Umapathi LK, Sankarasubbu M. MedMCQA: A Large-Scale Multi-Subject Multi-Choice Dataset for Medical Domain Question Answering. Conference on Health, Inference, and Learning, PMLR 174, 2022:248-260. https://proceedings.mlr.press/v174/pal22a.html
- Jin Q, Dhingra B, Liu Z, Cohen W, Lu X. PubMedQA: A Dataset for Biomedical Research Question Answering. EMNLP-IJCNLP, 2019. https://arxiv.org/abs/1909.06146
- Arora RK, Wei J, Soskin Hicks R, et al. HealthBench: Evaluating Large Language Models Towards Improved Human Health. arXiv:2505.08775, preprint, 2025. https://arxiv.org/abs/2505.08775
- Bedi S, Cui H, Fuentes M, et al. Holistic Evaluation of Large Language Models for Medical Tasks with MedHELM. Nature Medicine, 2026; doi:10.1038/s41591-025-04151-2; also arXiv:2505.23802. https://arxiv.org/abs/2505.23802
- OpenEvidence. OpenEvidence AI becomes the first AI in history to score above 90% on the United States Medical Licensing Examination (USMLE). Company announcement, July 2023. openevidence.com announcement
- Fierce Healthcare. OpenEvidence AI scores 100% on USMLE as company launches free explanation model for medical students. August 2025. fiercehealthcare.com article
- Pan J, Jian B, Hager P, et al. Beyond Benchmarks: Dynamic, Automatic and Systematic Red-Teaming Agents for Trustworthy Medical Language Models. arXiv:2508.00923, preprint (v2), 2026. https://arxiv.org/abs/2508.00923
- Farrow G, Li LS, Johnson J, Wang T, Torr P, Bolton W, Fehr FJ. When Rubrics Fail: Hallucinations Reveal Blind Spots in Medical AI Evaluation. arXiv:2609.12718, preprint, 2026. https://arxiv.org/abs/2609.12718
- Ekram T. Red-teaming Medical AI: Systematic Adversarial Evaluation of LLM Safety Guardrails in Clinical Contexts. medRxiv preprint, 2026. https://doi.org/10.64898/2026.02.26.26347212
- Chang CT, Farah H, Gui H, et al. Red teaming ChatGPT in medicine to yield real-world insights on model behavior. npj Digital Medicine 2025;8:149. https://pmc.ncbi.nlm.nih.gov/articles/PMC11889229/
- Balazadeh V, Cooper M, Pellow D, et al. Red Teaming Large Language Models for Healthcare. arXiv:2505.00467, preprint, 2025. https://arxiv.org/abs/2505.00467
- Feier AM, Kocaman V, Gul Y, et al. A Multi-Domain Red Teaming Framework for Safety, Robustness, and Fairness Evaluation of Medical Large Language Models. Text2Story 2026, CEUR Workshop Proceedings Vol. 4202; arXiv:2606.00027. https://arxiv.org/abs/2606.00027
FAQ
What is red teaming in healthcare AI?
Red teaming is a structured search for ways a healthcare AI product can fail. It can include attempts to get around safeguards and realistic clinical requests that lead to unsafe, misleading or inappropriate responses.
Is benchmarking the same as evaluation?
No. Benchmarking compares models on shared tasks. Evaluation checks whether a particular product meets requirements defined for its intended use.
Is a high benchmark score enough to deploy a clinical AI product?
No. A benchmark measures performance on one defined task. Product-specific evaluation and red teaming test the intended-use requirements and failure modes a benchmark leaves out.
How often should a healthcare AI product be red teamed?
At minimum, teams should consider red teaming before launch and after material model or product changes. The right frequency depends on the product's risk, rate of change, observed incidents and deployment context, and earlier findings should be retested as versions change.
Is red teaming part of evaluation?
They are related but distinct. Evaluation scores a product against cases and criteria the team has already defined. Red teaming searches for failures those cases miss. The two work best as a loop: each reproducible failure found in red teaming becomes a new evaluation case, so the product is checked for it in every later version.