EU Guide · Aug 2026
Build the evidence your EU AI medical device needs.
A practical 34-page guide for ML, data, regulatory, and quality teams building AI-enabled medical devices for the EU market.
Understand how the EU MDR and AI Act connect across classification, data governance, validation, technical documentation, change control, post-market surveillance, and multilingual deployment.

Why this matters
One device, two regulatory frameworks.
AI-enabled medical devices in Europe must meet requirements under the EU MDR and the AI Act.
The MDR covers the device itself: purpose, classification, safety, performance, clinical evaluation, post-market surveillance. The AI Act adds data governance, logging, transparency, human oversight, and robustness.
Teams clearing the same device in the US face a parallel set of data expectations, covered in our AI SaMD Data Playbook.
What's inside
The EU requirements that shape your AI evidence strategy
01
Regulatory framework
Where MDR and the AI Act overlap, where they don't, and what Article 2(13) may change once delegated acts land.
02
Regulatory pathways
The two routes to high-risk status under Article 6, and how they sit alongside Rule 11 device classification.
03
The minimum record a regulatory-ready dataset carries: source, consent, annotation provenance, model version.
04
Bias and subgroups
Four ways bias enters a medical model, and the identify, measure, mitigate, retest cycle that gets it out.
05
Evaluation metrics
Sensitivity, specificity, and calibration, and the three levels evidence clears before it counts as clinical proof.
06
The minimum record a regulatory-ready dataset carries: source, consent, annotation provenance, model version.
07
Change control
What makes a modification substantial under Article 43(4), and the questions to ask about third-party and foundation models.
08
Post-market surveillance
Three monitoring layers, how drift gets investigated rather than just detected, and what MDCG 2025-10 expects.
09
Language duties across MDR labeling, AI Act transparency, and technical documentation, and what neither regulation requires yet.
10
Case studies
Two worked scenarios. A chest X-ray triage tool taken through both classification tracks, and a 500,000-image dataset review that looks strong until subgroup and external-site performance are broken out.
Who the playbook is for
Written for the teams
who own the submission
Grayde is a division of Milestone Localization, a life science translation company founded in 2020. Milestone works with pharmaceutical, biotech, and medical device organisations across the full range of life science documentation: regulatory submissions, clinical trial materials, medical device labeling, and more.
Milestone holds ISO 9001, ISO 13485, and ISO 17100 certifications. Its network of over 1000s of verified medical and scientific experts spans 80+ languages. Grayde was built on that foundation.
ML & data engineers
Data scientists
Regulatory & quality
Building AI for an EU medical device?
Start with the evidence chain.
Download the guide and see how the MDR and AI Act evidence requirements connect, from your dataset to post-market monitoring.

