Evaluation

Ground Truth for Healthcare AI: What Clinician Disagreement Means to Model Development

21 Sep, 2026

Ground truth for healthcare AI and clinician disagreement

Research across several clinical specialties has measured how often doctors disagree with each other, with themselves, and with later-confirmed diagnoses. Anyone training or evaluating a healthcare AI model is building on top of those findings.

"Ground truth" is borrowed from satellite mapping, where you check the image by walking the field. That is a useful analogy for medicine, but only partly.

Some clinical tasks have strong confirmatory tests; a biopsy result or a later clinical outcome can establish the diagnosis with relatively high confidence. Many others rely on interpretation and consensus, and there a second opinion is the check. Second opinions agree with first opinions less often than anyone building a dataset would like.

Reliability studies across radiology, pathology, emergency medicine, cardiology, psychiatry and treatment planning have measured how often doctors disagree with each other, with themselves, and with later confirmation. Anyone who trains or evaluates a healthcare AI model is working on top of those findings.

The FDA's draft guidance on AI-enabled devices reflects this. It defines a reference standard as "the best available representative truth that can be used to define the true condition for each patient/case/record," uses "ground truth" as a synonym for it, and asks sponsors to describe how it was established, its uncertainty, and the intra- and/or inter-clinician variability behind it, as applicable1. Many clinical labels depend on interpretation, on definitions, and on the information available when they were assigned.

1. The starting point: how often medicine gets it wrong

Labels extracted from routine care can carry diagnostic and documentation errors. As a result, the error rate cannot be assumed; it has to be measured within the specific dataset being used to train or evaluate a model.

SettingWhat was measuredFindingSource
US, all care settingsEstimated serious harms (death or permanent disability) from misdiagnosis of 15 dangerous diseasesAbout 795,000 a year (plausible range 598,000 to 1,023,000); weighted error rate 11.1% for those 15 diseases, which account for about half of estimated serious harms 2Newman-Toker 2024
US outpatient careAdults experiencing a diagnostic error each yearAbout 5.08%, roughly 12 million adults, about half potentially harmful 3Singh 2014
US emergency departmentsVisits with at least one diagnostic error, systematic review5.7%, about 1 in 18; the estimate and its extrapolation were publicly disputed by the American College of Emergency Physicians 4AHRQ 2022
Autopsy series, 1966 to 2002Major diagnosis missed in life, median across 42 series reporting it23.5%; autopsied cases are selected and the series are historical 5Shojania 2003
Mayo Clinic, 286 referralsReferral diagnosis confirmed, changed or refined on specialist review12% unchanged, 21% completely changed, 66% refined; selected referrals, and refinement is not necessarily initial error 6Van Such 2017
RadiologyReported real-time error per read; retrospective error on abnormal studies3 to 5%; about 30%; two different designs 7Brady 2017
Internal medicine, 100 error casesCases where cognitive factors contributed74 of 100 selected error cases 8Graber 2005

None of these studies was about AI. They measure how often clinical judgments are later revised, refined, or overturned. That matters because models trained on routine clinical labels learn both the confirmed diagnoses and the errors or uncertainty embedded in those labels. Unless a reference dataset is built differently, the model is ultimately evaluated against the same mixture.

2. Experts disagree with each other

The literature on how well physicians agree goes back decades. A recurring finding, though not a universal one, is that agreement is high for clear-cut cases and lower for intermediate categories.

Imaging

In 1994, ten radiologists read the same 150 mammograms. For women who did not have cancer, the share recommended for immediate work-up ranged from 11% to 65%, depending on which radiologist was reading the data9. In clinical practice, across 83 radiologists and 216,783 screening examinations, the share of each radiologist's own caseload rated "dense" ranged from 6.3% to 84.5%10. Density assessment can influence recommendations for supplemental screening, so the reader matters.

How far readers and laboratories differ How far readers and laboratories differ Lowest and highest value across readers or labs. The unit differs by row; see the labels. 0% 20% 40% 60% 80% 100% Work-up recommended, women without cancer Same 150 films, 10 radiologists (Elmore 1994) Work-up recommended, women without cancer: 11% to 65% 11% 65% Work-up recommended, women with cancer Same 150 films, 10 radiologists (Elmore 1994) Work-up recommended, women with cancer: 74% to 96% 74% 96% Share of own caseload rated 'dense' Each radiologist's own exams, 83 readers (Sprague 2016) Share of own caseload rated 'dense': 6.3% to 84.5% 6.3% 84.5% Ki67 score, laboratory geometric mean Same 100 cases, local staining, 8 labs (Polley 2013) Ki67 score, laboratory geometric mean: 6.1% to 30.1% 6.1% 30.1%
Figure 1. Only the first two rows are a same-film experiment. The density row is the share of each radiologist's own clinical caseload rated dense, so patient mix also varies. The Ki67 row is each laboratory's geometric mean across the same 100 cases using locally stained material, not the extreme readings of one slide. Sources 9,10,21.
Data table
MeasureLowestHighestDesign
Work-up recommended, women without cancer11%65%Same 150 films, 10 radiologists (Elmore 1994)
Work-up recommended, women with cancer74%96%Same 150 films, 10 radiologists (Elmore 1994)
Share of own caseload rated 'dense'6.3%84.5%Each radiologist's own exams, 83 readers (Sprague 2016)
Ki67 score, laboratory geometric mean6.1%30.1%Same 100 cases, local staining, 8 labs (Polley 2013)

Similar variability appears for chest X-rays, CT nodules, retinal images and echocardiograms11,12,13,14. When Google built its reference standard for chest X-ray AI, three radiologists reviewed each of 3,780 images. On the first read, all three agreed on only 41.8% of images. Reaching 96.8% agreement required up to five rounds of adjudication, illustrating how much expert disagreement can exist even in a carefully constructed reference dataset.

Pathology

Pathology is often called the gold standard, and for clear-cut diagnoses it often is. In one study, 115 pathologists each interpreted a subset of 240 breast biopsy cases. Concordance with an expert reference was 96% for invasive breast cancer, but only 48% for atypia, an intermediate diagnostic category15. A similar pattern appeared in melanocytic lesions: 187 pathologists achieved 92% accuracy against expert consensus for nevi and mildly atypical lesions, but only 25% for moderately atypical lesions16.

Grading and scoring tasks, which are among the most common pathology tasks assigned to AI models, are even less reproducible. In one study, general pathologists achieved a kappa of 0.435 for grouped Gleason scores when compared with a consensus reference, indicating only moderate agreement on prostate cancer grading17. In a HER2 scoring study, 92 breast cancer cases received at least one IHC 0 reading from a panel of 18 pathologists; only 24 of them (26%) reached the study's threshold of at least 17 readers agreeing on 0 versus 1+18. Low-level HER2 scoring can now affect eligibility for specific treatments19. PD-L1 scoring is concordant on tumour cells and far less so on immune cells; Ki67, cervical cytology and Barrett's oesophagus dysplasia show their own reproducibility limits20,21,22,23.

The bedside and the emergency department

When 124 physicians read 36 selected ECGs with features suggesting a heart attack, inter-reader kappa was 0.33 and sensitivity 65%24. Using standardised vignettes, 87 triage nurses in three countries assigned the reference urgency level 59% of the time, and 44% of the time for the highest-acuity cases25. Physical examination and ECG interpretation more broadly show similar variability, and the NIH Stroke Scale scored kappa 0.33 among untrained raters and 0.61 after training in one small study26,27,28.

Psychiatry, treatment and prognosis

The DSM-5 field trials had two clinicians interview the same patients independently. Test-retest kappa was 0.28 for major depressive disorder and 0.20 for generalized anxiety disorder29. In a 2000 survey on one localized prostate cancer scenario, 93% of urologists named surgery as the preferred treatment while 72% of radiation oncologists called surgery and radiotherapy equivalent30. In one breast cancer study, tumour board review changed the surgical plan for about half of 149 referred patients31,32. And when 343 doctors estimated survival for 468 hospice patients, about 20% of predictions were within a third of the actual survival time33.

Several grading studies find lower reproducibility in intermediate categories: invasive cancer at 96% against atypia at 48%, nevi at 92% against moderately atypical lesions at 25%. Those intermediate categories are often the ones an AI model is bought to sort.

3. Experts disagree with themselves

If disagreement were only between clinicians, a single experienced reader could still be a stable reference standard.

Repeat-reading studies say otherwise.

In one study, three experienced abdominal radiologists each re-read 60 of 90 CT scans several months after issuing the original reports, with half of their scans being their own prior cases and half belonging to their colleagues'. The major discrepancy rate was 26% against colleagues and 32% against their own earlier reads, showing that even the same expert can reach a different conclusion when reviewing the same case again34.

Pathologists are not always consistent with their own earlier diagnoses either.

In one repeat-reading study, pathologists re-evaluated the same breast atypia biopsy cases at least nine months after their original interpretations. They agreed with their own earlier diagnosis only 53% of the time, while agreement between different pathologists on the same cases was 43%35.

Repeat readings can differ even within a single session.

In one study, twelve echocardiographers graded a set of mitral regurgitation cases that secretly included six contentious cases repeated three times. Only one of the twelve echocardiographers gave consistent ratings across all six repeated triplets36.

In another study, echocardiographers grading left ventricular function agreed with each other 50% of the time and with themselves 68% of the time, even when videos were shown again during the same session14.

A different line of evidence suggests that clinical decisions can also vary with context.

In an observational study, across 33 primary care practices, clinicians ordered breast cancer screening for 63.7% of eligible patients with 8 AM appointments, compared with 47.8% of those seen at 5 PM37. This was not a repeat-reading study of the same cases, but an association between appointment time and clinical decision-making.

Repeat readings differ, whether by a colleague or the same reader Repeat readings differ, whether by a colleague or the same reader All values are disagreement rates. Atypia and echo values are complements of the published agreement rates. Between two readers Same reader, second read 100% 75% 50% 25% 0% CT: between readers, 26% Breast atypia: between readers, 57% Echo LV grade: between readers, 50% CT: same reader, 32% Breast atypia: same reader, 47% Echo LV grade: same reader, 32% 26% 32% 57% 47% 50% 32% CT, major discrepancy Breast atypia, disagreement Echo LV grade, disagreement 90 scans, 60 re-reads per reader (Abujudeh 2010) 60 cases, 9+ months apart (Jackson 2017) 20 videos, repeated in one sitting (Cole 2015)
Figure 2. Repeat readings can differ substantially, although self-agreement was higher than between-reader agreement in the atypia and LV-grading studies; only the CT study found a higher self-discrepancy rate. The atypia and echo bars are 100 minus the published agreement rates (43% and 53%; 50% and 68%). In the CT study, 90 scans were read; each of three radiologists re-read 60, half their own and half colleagues'. The echo videos were repeated within the same session, not months apart. Sources 34,35,14.
Data table
TaskBetween readersSame readerDesign
CT, major discrepancy26%32%90 scans, 60 re-reads per reader (Abujudeh 2010)
Breast atypia, disagreement57%47%60 cases, 9+ months apart (Jackson 2017)
Echo LV grade, disagreement50%32%20 videos, repeated in one sitting (Cole 2015)

A single-reader label is not a fixed truth; it is one interpretation drawn from a range of plausible clinical judgments. That is why the FDA's draft guidance recommends reporting intra-reader and inter-reader variability, where applicable, when establishing a reference standard.

4. Labels from the medical record do not escape the problem

The obvious fix is to stop asking clinicians to label cases and instead use labels already present in the medical record, such as diagnosis codes, laboratory values, or timestamps. Most large clinical datasets are built this way. But the problem does not disappear; it shifts from expert interpretation to the definitions used to generate those labels. The same patient's record can receive different labels depending on which published clinical definition is applied.

Sepsis is the clearest example.

In one study of 11,791 adult ICU admissions, researchers applied six published definitions of sepsis to the exact same patients. Each definition was designed for a different purpose, including billing, surveillance, or research. Using explicit diagnosis codes, 9.0% of admissions were labelled as sepsis. The CMS definition labelled 11.0%, the CDC definition 31.9%, and Sepsis-3 labelled 49.1%38. The patients did not change; the positive sepsis cohort varied about 5.5-fold depending on the definition used.

Same 11,791 ICU admissions, six definitions of sepsis Same 11,791 ICU admissions, six definitions of sepsis Share of admissions given a positive sepsis label under each published definition. MIMIC-III, Johnson 2018. 60% 50% 40% 30% 20% 10% 0% Explicit codes: 9.0% CMS: 11.0% Martin: 14.7% Angus: 28.6% CDC: 31.9% Sepsis-3: 49.1% 9% 11% 14.7% 28.6% 31.9% 49.1% Explicit codes CMS Martin Angus CDC Sepsis-3
Figure 3. The admissions are the same; the positive sepsis cohort ranges from 9.0% to 49.1% of them, about a 5.5-fold difference. These definitions were built for different purposes (billing, surveillance, research) and are not six equivalent gold standards. The cohort is a selected adult ICU population. Source 38.
Data table
DefinitionPositive-label prevalence
Explicit codes9.0%
CMS11.0%
Martin14.7%
Angus28.6%
CDC31.9%
Sepsis-349.1%

Even a single definition leaves room for interpretation.

Sepsis-3, for example, defines the clinical criteria for sepsis but does not specify exactly when sepsis begins. One study tested three operational interpretations of Sepsis-3 onset: at organ dysfunction, at suspected infection, or at whichever came first. Training the same models using these three interpretations changed AUROC by up to 6 percentage points, while changing the model architecture with the interpretation held constant changed AUROC by 1 to 5 percentage points39. In other words, changing the label definition had a bigger effect than changing the model in that study.

A second ICU study found a similar problem with timing. When criteria-derived sepsis onset times were compared with clinician-assigned onset times, agreement on when sepsis began was only fair, even though clinicians agreed almost perfectly on whether sepsis was present40.

Changing the label definition can move AUROC more than changing the model The observed AUROC spread was zero to six percentage points when changing the onset interpretation and one to five percentage points when changing the model. Changing the label definition can move AUROC more than changing the model Observed spread in AUROC, percentage points, same ICU data. Cohen et al. 2024. 0 pts 2 pts 4 pts 6 pts 8 pts Change the onset interpretation, keep the model Three operational readings of Sepsis-3 onset Change the onset interpretation, keep the model: 0 pts to 6 pts 0 pts 6 pts Change the model, keep the interpretation Across model families Change the model, keep the interpretation: 1 pt to 5 pts 1 pt 5 pts
Figure 4. These are observed performance ranges in one study, not uncertainty intervals, and they do not show that any one interpretation is clinically truer. Source 39 .
Data table
ComparisonSmallest spreadLargest spread
Change the onset interpretation, keep the model0 pts6 pts
Change the model, keep the interpretation1 pt5 pts

Even diagnosis codes are an imperfect source of ground truth. A meta-analysis found that ICD-10 sepsis codes had a pooled sensitivity of 35% (95% CI 22 to 48%), based on heterogeneous, low-certainty evidence41.

Differences also appear at the population level. Across 409 US hospitals, sepsis incidence measured using clinical criteria remained relatively stable between 2009 and 2014, while sepsis incidence measured using insurance claims increased by about 10% per year42.

This context is important when interpreting evaluations of sepsis AI models. In the widely cited external validation of the Epic Sepsis Model, researchers evaluated the model on 38,455 hospitalisations using a reference standard based on a combination of diagnosis codes and clinical criteria. The model achieved an AUC of 0.63 and, at the alert threshold studied, missed 67% of sepsis cases43. That study evaluated one version of the model against one particular reference standard. It does not show that the reference standard caused the model's performance, but it illustrates how model evaluation depends on how the ground truth is defined.

5. Ground truth is not equally true for every patient

The reference standard has subgroups too. When a Stanford group built a dermatology dataset of 656 biopsy-confirmed images across diverse skin tones, published AI models showed relative ROC-AUC declines of 27% to 36% compared with their original evaluation sets, with the largest drops on the darkest skin tones. Board-certified dermatologists, judged against biopsy, were also less accurate on dark skin44. Had those labels come from dermatologists rather than pathology, that performance gap would likely have been much harder to detect. The reliability of a reference standard can vary across patient groups, not just across clinicians.

Several studies found lower agreement in the more challenging subgroup of the same task. In one breast biopsy study, pathologist concordance on breast biopsies was 81% in the lowest density category and 70% in the highest15. In paediatric pneumonia, disagreement between initial and expert chest X-ray interpretations was 11% in children aged five years and older and 26% in children under five45. In emergency triage, nurses reached the reference level for 66% of adult vignettes and 47% of paediatric vignettes25.

A model's subgroup performance claim is only as reliable as the subgroup labels it is evaluated against. If the reference standard is less consistent for certain patient groups, that uncertainty needs to be measured and reported rather than assumed away.

Agreement was lower in the harder subgroup of each study Grouped bar chart comparing agreement or accuracy in easier and harder subgroups across breast biopsy, chest X-ray, and triage studies. Agreement was lower in the harder subgroup of each study Reader agreement or accuracy against the study's reference, by subgroup. Easier subgroup Harder subgroup 100% 75% 50% 25% 0% Breast biopsy concordance, easier subgroup: 81% Chest X-ray agreement, easier subgroup: 89% Triage accuracy, easier subgroup: 66.2% Breast biopsy concordance, harder subgroup: 70% Chest X-ray agreement, harder subgroup: 74% Triage accuracy, harder subgroup: 46.9% 81% 70% 89% 74% 66.2% 46.9% Breast biopsy concordance Chest X-ray agreement, pneumonia Triage accuracy, vignettes Lowest vs highest density category (Elmore 2015) Age 5 and over vs under 5 (Elemraid 2014) Adult vs paediatric cases (Mistry 2018)
Figure 5. The breast biopsy comparison is between the extreme density categories, not all dense versus non-dense breasts. The chest X-ray comparison uses disjoint age groups (disagreement 11% versus 26%). The triage study used standardised vignettes rather than observed triage of real patients. Sources 15, 45, 25 .
Data table
TaskEasier subgroupHarder subgroupComparison
Breast biopsy concordance81%70%Lowest vs highest density category (Elmore 2015)
Chest X-ray agreement, pneumonia89%74%Age 5 and over vs under 5 (Elemraid 2014)
Triage accuracy, vignettes66.2%46.9%Adult vs paediatric cases (Mistry 2018)

6. Labels are made in conditions that do not match real practice

So far the variables have been who reads the case, how the condition is defined, and which patients are in the set.

There is another source of variation: the conditions under which the label is created.

In the clinic, a radiologist interprets an image alongside prior scans, the referral note and the patient's history. Some labelling workflows omit that context or constrain reading time. As a result, the reference label may be created under conditions that do not reflect real clinical practice.

An 11-month qualitative study of five radiology AI tools, conducted by three researchers inside a large US hospital, described how mismatches between labelling conditions and clinical practice undermined local evaluations. Tools that had performed well on published benchmarks often disappointed during hospital pilots. Physicians traced part of that gap to the way the reference labels had been created: radiologists were asked to label images without access to prior scans, referral notes, or the patient's clinical history, context they would routinely use in everyday practice46.

One department leader put it this way:

There's no gold standard. The standard we use is the radiologists' read, but is the radiologist right? We don't know!

Radiology department manager, quoted in Lebovitz, Levina and Lifshitz-Assaf, MIS Quarterly 2021

7. What this means for evaluating medical LLMs

The newest use of ground truth is physicians evaluating the answers produced by medical language models. Those scores are the reference standard for the evaluation, and the physicians producing them disagree with each other at rates the sections above would predict.

OpenAI's HealthBench was built with 262 physicians who had practice experience across 60 countries. In its meta-evaluation on consensus criteria, macro-F1 between physicians ranged across themes from 0.569 to 0.730, and macro-F1 between the model grader and physicians fell in a similar range; the authors summarise both as roughly 55% to 75%47.

Physician-physician versus model-physician agreement on rubric judgments Grouped bar chart comparing physician-physician and model-physician macro-F1 scores across five HealthBench themes. Physician-physician versus model-physician agreement on rubric judgments Macro-F1 for consensus criteria, by theme. HealthBench meta-evaluation, Table 5. Model = GPT-4.1 as grader. Physician vs physician Model vs physician 1.00 0.75 0.50 0.25 0.00 Emergency referrals: 0.647 Responding under uncertainty: 0.640 Response depth: 0.569 Health data tasks: 0.730 Context seeking: 0.646 Emergency referrals: 0.662 Responding under uncertainty: 0.679 Response depth: 0.572 Health data tasks: 0.683 Context seeking: 0.706 0.65 0.66 0.64 0.68 0.57 0.57 0.73 0.68 0.65 0.71 Emergency referrals Responding under uncertainty Response depth Health data tasks Context seeking Macro-F1 (0 to 1)
Figure 6. Values are macro-F1 on consensus criteria from the HealthBench meta-evaluation, not the fraction of all judgments on which physicians agree. Five of seven themes are shown; the remaining two (expertise-tailored communication 0.618 versus 0.610; global health 0.648 versus 0.706) follow the same pattern. Similar aggregate agreement does not establish equivalent clinical judgment. Source 47 .
Data table
ThemePhysician vs physician (macro-F1)Model vs physician (macro-F1)
Emergency referrals0.6470.662
Responding under uncertainty0.6400.679
Response depth0.5690.572
Health data tasks0.7300.683
Context seeking0.6460.706

A follow-up preprint decomposed that disagreement: physicians disagreed on 22.5% of prompt-completion-rubric combinations, and rubric criterion accounted for 15.8% of the variance, physician identity for 2.4%, with 81.8% left unexplained by the model48. In a German benchmark preprint with ten physicians and nine LLM graders, the best LLM grader reached kappa 0.694 against a physician-physician kappa of 0.709, but the physicians abstained more on difficult items while the models never did, and the graders showed lineage-dependent bias49. Med-PaLM 2 reported higher agreement: free-marginal kappa above 0.8 on ten of twelve axes and above 0.6 on the other two, with three ratings per evaluated answer50.

When a reference standard depends on expert judgment, its reproducibility is part of the evaluation. Similar model-expert and expert-expert agreement can help contextualise a score, but does not by itself establish equivalent clinical performance.

Two systems can achieve the same overall agreement while making very different errors, and those errors may have very different clinical consequences. Stronger references, error analysis, and outcome-based validation are needed to determine which disagreements matter in practice.

8. Building better ground truth

None of this diminishes the value of ground truth. It reframes ground truth as a measurement: something established through a defined method, with uncertainty that can be measured, reported, and improved. What that looks like depends on how the labels will be used.

For post-training data

Use more than one reader per item and keep every reader's answer, not only the resolved one. Disagreement between experts is information, not something to discard. A case that three experts disagree on is a different training example from one they all agreed on, and a model can be taught the difference.

A stronger approach is for clinicians to label cases independently and blinded to one another's assessments, followed by adjudication where disagreements occur. In a diabetic retinopathy study, a simple majority vote among ophthalmologists missed cases that were identified during specialist adjudication, showing that adjudication produced a more reliable reference standard than majority vote alone13.

  • Give readers what the clinic has: priors, history, the referral question.
  • Use discrepancy analysis to target training, image-quality review, guidelines and adjudication. In the retinopathy study, 36% of 193 discrepancies between majority and adjudicated labels involved missed microaneurysms and 20% involved image artefacts13.
  • Match the reader to the task. In companion studies of Gleason grading, general pathologists reached kappa 0.435 for grouped scores against consensus, while urologic pathologists reached weighted kappa 0.56 to 0.70; the metrics differ, so the comparison is indicative rather than exact17,51.

For evaluations

Before evaluating a model, evaluate the reference standard itself. Report inter-reader agreement and, where applicable, intra-reader agreement for the clinicians who created the reference set, as recommended in the FDA's draft guidance for AI-enabled medical devices1. A model's performance score is much more meaningful when it is presented alongside the panel's own level of agreement.

Where more than one clinically valid label definition exists, run the evaluation under each defensible definition and report the range of results. In the sepsis example, changing the operational label definition changed model performance by up to 6 AUROC points.

Keep the clinicians who build the reference standard separate from the clinicians who evaluate model performance, consistent with the FDA's guidance for radiology AI devices52. Agreement should be reported by patient subgroup, since the reference standard may be less reliable in the same groups where the model performs less consistently. And whenever an objective anchor exists, such as pathology or a confirmed clinical outcome, it should be used while acknowledging its own limitations and error rate.

For reporting

A model's performance should be reported alongside the details of the reference standard used to evaluate it. That includes how many clinicians labelled the data, their qualifications, whether they were blinded, the adjudication process, the agreement statistics used, and how many cases changed during adjudication.

Reference standards should also be versioned, with each evaluation reporting exactly which version was used. And instead of reporting only the final resolved label, teams should report the structure of disagreement: which categories generated disagreement, how often they did, and why.

Caveats

This review combines older clinical reliability studies with more recent AI-specific evaluations. The studies span 1988 to 2026, and the older ones predate current practice, imaging and guidelines. The direction of the findings is consistent; the exact figures are not comparable between studies, and several are from selected cases or vignettes rather than routine practice.

Kappa, weighted kappa, intraclass correlation, macro-F1, per cent agreement and Krippendorff's alpha are different statistics on different scales. Each figure is quoted in the statistic its authors used and labelled as such. Low agreement is not the same as low accuracy: some disagreement is legitimate uncertainty about an intermediate case. Adjudication can resolve some disagreements, while others should remain explicitly uncertain.

The AHRQ emergency department estimate was publicly disputed by the American College of Emergency Physicians. The 2025 and 2026 arXiv papers cited are preprints.

The FDA's phrase is the right one to end on. A reference standard is the best available representative truth. Best available means someone chose it. Representative means it stands in for something it is not. Reference standards deserve explicit validation and transparent reporting, and teams that provide both will report numbers that hold up in the clinic.

Grayde builds adjudicated, multi-reader reference sets and evaluations for healthcare and life science AI teams, with the disagreement analysis reported alongside the result. Contact us to run a pilot for your clinical AI application.

References

  1. US FDA. Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations. Draft guidance for industry and FDA staff, January 2025 (nonbinding). https://www.fda.gov/media/184856/download
  2. Newman-Toker DE, Nassery N, Schaffer AC, et al. Burden of serious harms from diagnostic error in the USA. BMJ Quality & Safety 2024;33:109-120. https://pmc.ncbi.nlm.nih.gov/articles/PMC10792094/
  3. Singh H, Meyer AND, Thomas EJ. The frequency of diagnostic errors in outpatient care: estimations from three large observational studies involving US adult populations. BMJ Quality & Safety 2014;23:727-731. https://pmc.ncbi.nlm.nih.gov/articles/PMC4145460/
  4. Newman-Toker DE, Peterson SM, Badihian S, et al. Diagnostic Errors in the Emergency Department: A Systematic Review. AHRQ Comparative Effectiveness Review No. 258, 2022 (with 2023 addendum). https://www.ncbi.nlm.nih.gov/books/NBK588118/
  5. Shojania KG, Burton EC, McDonald KM, Goldman L. Changes in rates of autopsy-detected diagnostic errors over time: a systematic review. JAMA 2003;289:2849-2856. https://doi.org/10.1001/jama.289.21.2849
  6. Van Such M, Lohr R, Beckman T, Naessens JM. Extent of diagnostic agreement among medical referrals. Journal of Evaluation in Clinical Practice 2017;23:870-874. https://pubmed.ncbi.nlm.nih.gov/28374457/
  7. Brady AP. Error and discrepancy in radiology: inevitable or avoidable? Insights into Imaging 2017;8:171-182. https://doi.org/10.1007/s13244-016-0534-1
  8. Graber ML, Franklin N, Gordon R. Diagnostic error in internal medicine. Archives of Internal Medicine 2005;165:1493-1499. https://jamanetwork.com/journals/jamainternalmedicine/fullarticle/486642
  9. Elmore JG, Wells CK, Lee CH, Howard DH, Feinstein AR. Variability in radiologists' interpretations of mammograms. New England Journal of Medicine 1994;331:1493-1499. https://www.nejm.org/doi/full/10.1056/NEJM199412013312206
  10. Sprague BL, Conant EF, Onega T, et al. Variation in mammographic breast density assessments among radiologists in clinical practice: a multicenter observational study. Annals of Internal Medicine 2016;165:457-464. https://pmc.ncbi.nlm.nih.gov/articles/PMC5050130/
  11. Majkowska A, Mittal S, Steiner DF, et al. Chest radiograph interpretation with deep learning models: assessment with radiologist-adjudicated reference standards and population-adjusted evaluation. Radiology 2020;294:421-431. https://pubs.rsna.org/doi/10.1148/radiol.2019191293
  12. Armato SG, McLennan G, Bidaut L, et al. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): a completed reference database of lung nodules on CT scans. Medical Physics 2011;38:915-931. https://www.nist.gov/publications/lung-image-database-consortium-lidc-and-image-database-resource-initiative-idri
  13. Krause J, Gulshan V, Rahimy E, et al. Grader variability and the importance of reference standards for evaluating machine learning models for diabetic retinopathy. Ophthalmology 2018;125:1264-1272. https://research.google/pubs/grader-variability-and-the-importance-of-reference-standards-for-evaluating-machine-learning-models-for-diabetic-retinopathy/
  14. Cole GD, Dhutia NM, Shun-Shin MJ, et al. Defining the real-world reproducibility of visual grading of left ventricular function and visual estimation of left ventricular ejection fraction: impact of image quality, experience and accreditation. International Journal of Cardiovascular Imaging 2015;31:1303-1314. https://link.springer.com/article/10.1007/s10554-015-0659-1
  15. Elmore JG, Longton GM, Carney PA, et al. Diagnostic concordance among pathologists interpreting breast biopsy specimens. JAMA 2015;313:1122-1132. https://jamanetwork.com/journals/jama/fullarticle/2203798
  16. Elmore JG, Barnhill RL, Elder DE, et al. Pathologists' diagnosis of invasive melanoma and melanocytic proliferations: observer accuracy and reproducibility study. BMJ 2017;357:j2813. https://pubmed.ncbi.nlm.nih.gov/28659278/
  17. Allsbrook WC Jr, Mangold KA, Johnson MH, Lane RB, Lane CG, Epstein JI. Interobserver reproducibility of Gleason grading of prostatic carcinoma: general pathologist. Human Pathology 2001;32:81-88. https://pubmed.ncbi.nlm.nih.gov/11172299/
  18. Fernandez AI, Liu M, Bellizzi A, et al. Examination of low ERBB2 protein expression in breast cancer tissue. JAMA Oncology 2022;8:607-610. https://pmc.ncbi.nlm.nih.gov/articles/PMC8814969/
  19. US FDA. FDA approves fam-trastuzumab deruxtecan-nxki for unresectable or metastatic HR-positive, HER2-low or HER2-ultralow breast cancer. January 2025. https://www.fda.gov/drugs/resources-information-approved-drugs/fda-approves-fam-trastuzumab-deruxtecan-nxki-unresectable-or-metastatic-hr-positive-her2-low-or-her2
  20. Rimm DL, Han G, Taube JM, et al. A prospective, multi-institutional, pathologist-based assessment of 4 immunohistochemistry assays for PD-L1 expression in non-small cell lung cancer. JAMA Oncology 2017;3:1051-1058. https://pubmed.ncbi.nlm.nih.gov/28278348/
  21. Polley MYC, Leung SCY, McShane LM, et al. An international Ki67 reproducibility study. Journal of the National Cancer Institute 2013;105:1897-1906. https://academic.oup.com/jnci/article-abstract/105/24/1897/2517589
  22. Stoler MH, Schiffman M, for the ALTS Group. Interobserver reproducibility of cervical cytologic and histologic interpretations: realistic estimates from the ASCUS-LSIL Triage Study. JAMA 2001;285:1500-1505. https://pubmed.ncbi.nlm.nih.gov/11255427/
  23. Montgomery E, Bronner MP, Goldblum JR, et al. Reproducibility of the diagnosis of dysplasia in Barrett esophagus: a reaffirmation. Human Pathology 2001;32:368-378. https://pubmed.ncbi.nlm.nih.gov/11331953/
  24. McCabe JM, Armstrong EJ, Ku I, et al. Physician accuracy in interpreting potential ST-segment elevation myocardial infarction electrocardiograms. Journal of the American Heart Association 2013;2:e000268. https://pmc.ncbi.nlm.nih.gov/articles/PMC3835230/
  25. Mistry B, Stewart De Ramirez S, Kelen G, et al. Accuracy and reliability of emergency department triage using the Emergency Severity Index: an international multicenter assessment. Annals of Emergency Medicine 2018;71:581-587. https://pubmed.ncbi.nlm.nih.gov/29174836/
  26. Spiteri MA, Cook DG, Clarke SW. Reliability of eliciting physical signs in examination of the chest. Lancet 1988;331:873-875. https://pubmed.ncbi.nlm.nih.gov/2895374/
  27. Cook DA, Oh SY, Pusic MV. Accuracy of physicians' electrocardiogram interpretations: a systematic review and meta-analysis. JAMA Internal Medicine 2020;180:1461-1471. https://jamanetwork.com/journals/jamainternalmedicine/fullarticle/2771093
  28. Schmülling S, Grond M, Rudolf J, Kiencke P. The need for training when using the NIH Stroke Scale. 1998 (journal record via Thieme). https://www.thieme-connect.de/products/all/doi/10.1055/s-2007-1017605
  29. Regier DA, Narrow WE, Clarke DE, et al. DSM-5 field trials in the United States and Canada, part II: test-retest reliability of selected categorical diagnoses. American Journal of Psychiatry 2013;170:59-70. https://psychiatryonline.org/doi/10.1176/appi.ajp.2012.12070999
  30. Fowler FJ Jr, McNaughton Collins M, Albertsen PC, Zietman A, Elliott DB, Barry MJ. Comparison of recommendations by urologists and radiation oncologists for treatment of clinically localized prostate cancer. JAMA 2000;283:3217-3222. https://pubmed.ncbi.nlm.nih.gov/10866869/
  31. Newman EA, Guest AB, Helvie MA, et al. Changes in surgical management resulting from case review at a breast cancer multidisciplinary tumor board. Cancer 2006;107:2346-2351. https://deepblue.lib.umich.edu/handle/2027.42/55868?show=full
  32. Lamb BW, Brown KF, Nagpal K, Vincent C, Green JSA, Sevdalis N. Quality of care management decisions by multidisciplinary cancer teams: a systematic review. Annals of Surgical Oncology 2011;18:2116-2125. https://link.springer.com/article/10.1245/s10434-011-1675-6
  33. Christakis NA, Lamont EB. Extent and determinants of error in doctors' prognoses in terminally ill patients: prospective cohort study. BMJ 2000;320:469-473. https://pmc.ncbi.nlm.nih.gov/articles/PMC27288/
  34. Abujudeh HH, Boland GW, Kaewlai R, et al. Abdominal and pelvic computed tomography (CT) interpretation: discrepancy rates among experienced radiologists. European Radiology 2010;20:1952-1957. https://link.springer.com/article/10.1007/s00330-010-1763-1
  35. Jackson SL, Frederick PD, Pepe MS, et al. Diagnostic reproducibility: what happens when the same pathologist interprets the same breast biopsy specimen at two points in time? Annals of Surgical Oncology 2017;24:1234-1241. https://pubmed.ncbi.nlm.nih.gov/27913946/
  36. Thomas N, Unsworth B, Ferenczi EA, Davies JE, Mayet J, Francis DP. Intraobserver variability in grading severity of repeated identical cases of mitral regurgitation. American Heart Journal 2008;156:1089-1094. https://pubmed.ncbi.nlm.nih.gov/19033003/
  37. Hsiang EY, Mehta SJ, Small DS, et al. Association of primary care clinic appointment time with clinician ordering and patient completion of breast and colorectal cancer screening. JAMA Network Open 2019;2:e193403. https://jamanetwork.com/journals/jamanetworkopen/fullarticle/2733171
  38. Johnson AEW, Aboab J, Raffa JD, et al. A comparative analysis of sepsis identification methods in an electronic database. Critical Care Medicine 2018;46:494-499. https://pmc.ncbi.nlm.nih.gov/articles/PMC5851804/
  39. Cohen SN, Foster J, Foster P, et al. Subtle variation in sepsis-III definitions markedly influences predictive performance within and across methods. Scientific Reports 2024;14:1920. https://doi.org/10.1038/s41598-024-51989-6
  40. Lindner HA, Schamoni S, Kirschning T, et al. Ground truth labels challenge the validity of sepsis consensus definitions in critical illness. Journal of Translational Medicine 2022;20:27. https://link.springer.com/article/10.1186/s12967-022-03228-7
  41. Liu B, Hadzi-Tosev M, Liu Y, et al. Accuracy of International Classification of Diseases, 10th Revision codes for identifying sepsis: a systematic review and meta-analysis. Critical Care Explorations 2022;4:e0788. https://pubmed.ncbi.nlm.nih.gov/36382338/
  42. Rhee C, Dantes R, Epstein L, et al. Incidence and trends of sepsis in US hospitals using clinical vs claims data, 2009-2014. JAMA 2017;318:1241-1249. https://pubmed.ncbi.nlm.nih.gov/28903154/
  43. Wong A, Otles E, Donnelly JP, et al. External validation of a widely implemented proprietary sepsis prediction model in hospitalized patients. JAMA Internal Medicine 2021;181:1065-1070. https://pubmed.ncbi.nlm.nih.gov/34152373/
  44. Daneshjou R, Vodrahalli K, Novoa RA, et al. Disparities in dermatology AI performance on a diverse, curated clinical image set. Science Advances 2022;8:eabq6147. https://www.science.org/doi/10.1126/sciadv.abq6147
  45. Elemraid MA, Muller M, Spencer DA, et al. Accuracy of the interpretation of chest radiographs for the diagnosis of paediatric pneumonia. PLOS One 2014;9:e106051. https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0106051
  46. Lebovitz S, Levina N, Lifshitz-Assaf H. Is AI ground truth really true? The dangers of training and evaluating AI tools based on experts' know-what. MIS Quarterly 2021;45:1501-1526. https://www.law.nyu.edu/sites/default/files/Lebovitz,%20Levina,%20Lifshitz-Assaf,%20MISQ,%202021,%20Published.pdf
  47. Arora RK, Wei J, Soskin Hicks R, et al. HealthBench: evaluating large language models towards improved human health. arXiv:2505.08775 (preprint, v1), 2025. https://arxiv.org/abs/2505.08775
  48. Borgohain and Mariathas. Decomposing physician disagreement in HealthBench. arXiv:2602.22758 (preprint), 2026. https://arxiv.org/abs/2602.22758
  49. Philipp W, Fassbender F, Fister D, et al. Clinician-level agreement without clinical caution: LLM evaluator limits in medical AI benchmarking. arXiv:2607.01103 (preprint), 2026. https://arxiv.org/abs/2607.01103
  50. Singhal K, Tu T, Gottweis J, et al. Toward expert-level medical question answering with large language models. Nature Medicine 2025;31:943-950. https://www.nature.com/articles/s41591-024-03423-7
  51. Allsbrook WC Jr, Mangold KA, Johnson MH, et al. Interobserver reproducibility of Gleason grading of prostatic carcinoma: urologic pathologists. Human Pathology 2001;32:74-80. https://pubmed.ncbi.nlm.nih.gov/11172298/
  52. US FDA. Clinical Performance Assessment: Considerations for Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device Data in Premarket Notification (510(k)) Submissions. Guidance for industry and FDA staff, 2022 (nonbinding). https://www.fda.gov/media/77642/download

FAQ

What is a reference standard in healthcare AI, and how is it different from ground truth?

A reference standard is the best available representative truth used to label each case in a dataset, such as a diagnosis or a treatment outcome.

The FDA's draft guidance for AI-enabled devices uses "ground truth" as a synonym for reference standard. Neither term means an error-free label. It means the most defensible label available, established through a defined method with known uncertainty.

How often do doctors disagree with each other on the same case?

It depends heavily on the task and how clear-cut the case is. Agreement is often high for obvious cases and much lower for intermediate ones, such as atypia in breast biopsies (48% concordance) versus invasive cancer (96%). In some studies, such as ECG interpretation for suspected heart attacks, agreement among readers has been as low as a kappa of 0.33.

Can the same doctor disagree with their own earlier diagnosis?

Yes. Repeat-reading studies show this happens regularly. In one study, radiologists re-reading their own CT scans months later reached a different major conclusion 32% of the time, a higher rate than their disagreement with colleagues on the same cases (26%).

Why does changing a clinical definition affect an AI model's performance?

Because the label, not just the model, determines what the model is being trained or evaluated against. In one study, applying six different published sepsis definitions to the same 11,791 ICU admissions produced positive-label rates ranging from 9.0% to 49.1%. In another, changing only the operational definition of sepsis onset shifted a model's AUROC by up to 6 percentage points, more than changing the model architecture did.

What does the FDA expect from a reference standard used to evaluate AI-enabled medical devices?

The FDA's draft guidance asks sponsors to describe how the reference standard was established, its uncertainty, and the inter-reader and intra-reader variability behind it, where applicable. It also recommends keeping the clinicians who build the reference standard separate from those who evaluate the model's performance against it.

Build a reference standard you can trust your model's score on.

Grayde builds adjudicated, multi-reader reference sets for healthcare AI.